House Stream Gage Daily Averages, 1993-2012

Summary

Abstract: 

As part of the Long Term Ecological Research (LTER) project in the McMurdo Dry Valleys of Antarctica, a systematic sampling program has been undertaken to monitor the glacial meltwater streams in that region. These tables contain averages data pertaining to continuous monitored water quality and quantity parameters measured with automatic recording devices on streams in this region. Specifically, this metadata record describes the hydrology daily averages data for the House stream at McMurdo Dry Valleys. Due to Lake level raise, measurement stops on Dec 2012.

Date Range: 

Friday, January 1, 1993 to Monday, December 31, 2012

...or query the data clicking the:

Variables: 

STRMGAGEID
  • Label: strmgageid
  • Definition: Code representing stream gage
  • Type: Nominal
  • Missing values: None specified
DATE_TIME
  • Label:
  • Definition: Date on which measurement was made
  • Type: Date/time
  • Date format: MM/DD/YYYY
  • Missing values: None specified
AVG_DISCHARGE
  • Label: Average Discharge
  • Definition: Average stream discharge, measured in liters per second
  • Type: Physical quantity
  • Unit: litersPerSecond
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = None given
STDDEV_DISCHARGE
  • Label: STD Discharge
  • Definition: Stadard deviation of the Stream discharge value distribution
  • Type: Physical quantity
  • Unit: litersPerSecond
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = None given
MIN_DISCHARGE
  • Label: Minimum Discharge Rate
  • Definition: Minimum of the Stream discharge
  • Type: Physical quantity
  • Unit: litersPerSecond
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = None given
MAX_DISCHARGE
  • Label: Maximum Discharge Rate
  • Definition: Maximum of the Discharge Rate
  • Type: Physical quantity
  • Unit: litersPerSecond
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = None given
N_DISCHARGE
  • Label: Number of Observations
  • Definition: Number of observations for the daily stats.
  • Type: Physical quantity
  • Unit: dimensionless
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
TDAILY_DISCHARGE
  • Label: Total Daily Discharge
  • Definition: The Stream total daily discharge
  • Type: Physical quantity
  • Unit: liter
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: 0.01
  • Missing values:
    • Null = None given
AVG_TEMP
  • Label: Average Temperature
  • Definition: Average water temperature in celsius
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
STDDEV_TEMP
  • Label: std temperature
  • Definition: Standard deviation of the water temperature distribution
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
MIN_TEMP
  • Label: Minimum Temperature
  • Definition: The minimum temperature
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
MAX_TEMP
  • Label:
  • Definition: Maximum temperature
  • Type: Physical quantity
  • Unit: celsius
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
N_TEMP
  • Label: Number of Observations
  • Definition: Number of observations for the daily stats.
  • Type: Physical quantity
  • Unit: dimensionless
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
AVG_COND
  • Label: Average Conductivity
  • Definition: Average Conductivity
  • Type: Physical quantity
  • Unit: microsiemens/cm
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
STDDEV_COND
  • Label:
  • Definition: Standard deviation of the conductivity
  • Type: Physical quantity
  • Unit: microsiemens/cm
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
MIN_COND
  • Label:
  • Definition: Minimum Conductivity
  • Type: Physical quantity
  • Unit: microsiemens/cm
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
MAX_COND
  • Label:
  • Definition: Maximum Conductivity
  • Type: Physical quantity
  • Unit: microsiemens/cm
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified
N_COND
  • Label: Number of Observations
  • Definition: Number of observations for the daily stats.
  • Type: Physical quantity
  • Unit: dimensionless
  • Maximum: Not specified
  • Minimum: Not specified
  • Precision: Not specified
  • Missing values: None specified

DOI: 

10.6073/pasta/8d150ffb0fb798ee8a2e004208877882

Short name: 

HOUSE_DAILY_HYDRO

Data set ID: 

9116
People

Owner/Creator: 

Contact: 

Additional Project roles: 

Field Crew
Data Manager